About 77,100 results
Open links in new tab
  1. Modbus: The Original Industrial Fieldbus Protocol

    Sep 2, 2025 · This article introduces Modbus, an industrial protocol that laid the foundation for fieldbus communication in industrial systems.

  2. Introduction to Modbus | Digital Data Acquisition and Networks in ...

    Modbus data frames The Modbus communication standard defines a set of commands for reading (receiving) and writing (transmitting) data between a master device and one or more slave devices …

  3. Modbus client application | Automation & Control Engineering Forum

    Jan 9, 2024 · Open Modbus adds two other IEEE754 32 bit floating formats with its LE button which selects between Big Endian and Little Endian. Win-tech two standard FP formats correspond to the …

  4. Modbus TCP - What is the correct usage of Unit ID?

    Jan 26, 2012 · The unit ID is used when dealing with Modbus Bridges. Typical bridges convert Modbus TCP to Modbus serial or Modbus plus. The Unit ID is either the device Id of serial device or it is index …

  5. Modbus Time Out Error | Automation & Control Engineering Forum

    Aug 12, 2019 · Modbus slaves can not initiate a transaction - cannot send on their own. The problem could be almost anything - Devices must be Modbus enabled. Just because a device has a serial …

  6. Modbus over Ethernet | Automation & Control Engineering Forum

    Jun 25, 2008 · Modbus is a protocol. You can use Modbus protocol over Ethernet, it is then called Modbus TCP/IP. Commonly used by Schneider Electric, as Schneider bought the company Modicon, …

  7. How to find unknown Slave id on MODBUS Serial Communication

    Feb 9, 2025 · Since the sensors were connected via daisy chain, only one comm port was in use, so all the sensors used the same serial comm settings, baud rate, parity, stop bit. So what worked …

  8. Modbus TCP cable | Automation & Control Engineering Forum

    Jan 15, 2025 · Hello, Is it possible to run Modbus TCP protocol if cable lenght is 130-140m? It will work if I use cat6 instead of cat5? do you have experience with that?

  9. Confused: Modbus TCP vs. Modbus RTU Over TCP - Control.com

    May 19, 2011 · Modbus RTU over TCP/IP is typically used by serial servers where you can have an Modbus Ethernet client communicating with multiple Modbus RTU- RS485 slaves, by way of a serial …

  10. Does Slave ID field have significance in MODBUS TCP

    Apr 26, 2003 · Hi All, In case of MODBUS TCP should the Slave ID be checked by a slave when it receives a frame? I am asking this question because in case of MODBUS TCP (unlike MODBUS …