  1. Navien Tankless Flush Problem: No Flow Out Hot Service Port

    Feb 28, 2026 · Cleaned the Navien cold inlet filter screen — it was basically clean. Tried reverse-flow pump test (pump into hot service, return out cold service) — also no circulation. Why this seems odd: …

  2. Navien NPE-240A Recirculation Question - Love Plumbing & Remodel

    Mar 5, 2022 · Hi all, we had a Navien NPE-240A installed in 2014, and have been happy with it. We did have a weird issue with water temperature being colder than expected occasionally, but it always …

  3. Navien NPE-240A and NaviCirc Installation Question

    Oct 25, 2021 · Hello, I just had my Navien NPE-240A (EDIT: It's actually an NPE-240A2) and NaviCirc installed today. First time tankless user. I was reviewing the manual and installation after they left, …

  4. Navien NPE-180A nightmare... - Love Plumbing & Remodel

    Feb 11, 2020 · Navien 'A' (Advanced) models include a recirculation pump and a small buffer tank to reduce the cold water sandwich effect common with other tankless systems. If the water in the buffer …

  5. Navien NPE-240A Water Temperature Problem - Love Plumbing

    Nov 22, 2021 · Navien NPE-240A Installed December 2013 External re-circulation loop installed Scale filter installed at cold water inlet Repair history: March 2016: PC Board & Gas Valve failure. Both …

  6. Controling Navien NPE internal recirculation pump

    Dec 15, 2016 · Does anyone know the logic behind how Navien controls their internal recirculation pump when it is circulating with an external loop? This would be with the second dip switch in the "On" …

  7. Purging Air from Multi Zone System - Navien 240

    Jan 3, 2025 · Its a Navien 240 tankless with 6 zones. 5 of the zones are to areas of the house (2 top, 2 bottom, 1 converted garage, 1 to an indirect hot water heater). they pumps are automatic variable …

  8. Navien NPE 240A with Navicirc Valves - Love Plumbing & Remodel

    Jun 15, 2020 · The Navien's Cold Inlet connection allows only fresh water to enter the heat exchanger directly as hot water is being consumed. Since the recirculation pump is to receive water from the …

  9. Navien NPE240A- Navilink,Navilink App, Recirculation settings And ...

    Jan 15, 2020 · Navien NPE 240A— Navilink recirculation—some customer insights. I have had The Navien NPE240A for about two years now and the unit has worked flawlessly, but it has taken me a …

  10. Navien Combi Boiler with Hydronic Air Handler

    Jan 26, 2022 · First let me say, I am new to Combi-Boilers, so bare with me if I ask dumb questions. I recently converted from Oil to Gas for many reasons (including getting a whole house generator). I …